CARTO 3 System
The CARTO 3 System is the next generation 3D mapping system from Biosense Webster. Building on the accuracy of CARTO System magnetic navigation technology, the CARTO 3 System provides electrophysiologists with three key capabilities.
| Advanced Catheter Location (ACL) Technology Hybrid Technology combines magnetic location technology and current-based visualization data to provide accurate tip and curve visualization |
![]() Image © Montreal Heart Institute, Canada 2009 |
| Fast Anatomical Mapping (FAM) Leading-edge technology creates a map as fast you can move the catheter allowing the rapid creation of high-resolution, CT-like maps with proven CARTO System accuracy |
![]() Image © Peter Munk Cardiac Centre, Toronto General Hospital, Canada 2009 |
| CONNECTION OF CHOICE New Patient Interface Unit (PIU) provides a central connection point for catheters and equipment. New catheters and cables have been designed to complement the CARTO3 System. These are integral to the system's new capabilities. |
![]() |
Related Products
CARTOMERGE Image Integration Module
»
CARTOSOUND Image Integration Module with 3D SoundStar catheter
»
CARTO RMT Electoanatomical Mapping System
»
- NAVISTAR Navigation and Ablation Catheters/Thermistor
- NAVISTAR Navigation and Ablation Catheters/Thermocouple
- NAVISTAR Soft Tip Navigation and Ablation Catheters/Thermistor
- NAVISTAR Soft Tip Navigation and Ablation Catheters/Thermocouple
- NAVISTAR DS Navigation and Ablation Catheters
- NAVISTAR THERMOCOOL™ Irrigated Tip Ablation Catheters
Education and Training
CARTO XP System e-Learning Modules
Find out more
»
Register here
»
- Download brochure
on the e-Learning modules
Related Documents
CARTO XP System brochure
CARTO XP System specifications
Kottkamp H, et al. Electromagnetic versus fluoroscopic mapping of the inferior isthmus for ablation of typical atrial flutter: A prospective randomized study. Circulation. 2000.
Full text
»
Nakagawa H, Jackman WM. Use of a three-dimensional, nonfluoroscopic mapping system for catheter ablation of typical atrial flutter. Pacing Clin Electrophysiol. 1998.
Abstract
»
Stevenson WG, et al. Identification and ablation of macroreentrant ventricular tachycardia with the CARTO electroanatomical mapping system. Pacing Clin Electrophysiol. 1998.
Abstract
»
Gepstein L, et al. A novel method for nonfluoroscopic catheter-based electroanatomical mapping of the heart. In vitro and in vivo accuracy results.
Circulation. 1997.
Full text
»
Shah DC, et al. Three-dimensional mapping of the common atrial flutter circuit in the right atrium. Circulation. 1997.
Full text
»
Shpun S, et al. Guidance of radiofrequency endocardial ablation with real-time three-dimensional magnetic navigation system. Circulation. 1997.
Full text
»