CARTO XP EP Navigation System
The CARTO XP Navigation System was the world’s first 3-D electroanatomical navigation system. It provides unparalleled views of the electrical activity of the heart through real-time data on 3-D, color-coded cardiac maps. It also ensures precise real-time tracking of catheter location, allowing for safe and accurate diagnosis.
Designed to minimize RF applications, unnecessary radiation exposure and procedure times, the CARTO XP Navigation System improves location accuracy and site-targeting results while maintaining an excellent safety profile. As a result, it provides the physician with the potential to perform more procedures, more rapidly than conventional fluoroscopy.
Platform flexibility allows physicians to easily upgrade performance and add functionality.
CARTOMERGE Module merges pre-acquired CT or MRI images with electroanatomical information
CARTO RMT System enables remote and automated procedure navigation for greater reproducibility
The CARTO XP Navigation System can be fully interfaced with the CardioLab® EP monitoring system and is compatible with all EP monitoring systems and radiofrequency generators on the market
Accessories
| Item | Catalog Number |
|---|---|
| CARTO XP Workstation | M-4700-96 |
| Color Computer Printer | M-5389-05 |
| Carts | M-5453-01 |
| 6 ft Power Strip | M-5404-03 |
| 15 ft Power Strip | M-5404-04 |
| 0.5 KVA Isolation Transformer | M-5401-01 |
| 1.5 KVA Isolation Transformer | M-5401-02 |
Related Products
CARTOMERGE Image Integration Module »
- NAVISTAR Navigation and Ablation Catheters/Thermistor
- NAVISTAR Navigation and Ablation Catheters/Thermocouple
- NAVISTAR Soft Tip Navigation and Ablation Catheters/Thermistor
- NAVISTAR Soft Tip Navigation and Ablation Catheters/Thermocouple
- NAVISTAR DS Navigation and Ablation Catheters
- NAVISTAR THERMOCOOL™ Irrigated Tip Ablation Catheters
- QWIKSTAR Navigation and Ablation Catheters
- QWIKSTAR DS Navigation and Ablation Catheters
- REFSTAR with QWIKPATCH External Reference Patch
- Stockert 70 RF Generator
Education and Training
CARTO XP System e-Learning Modules
Find out more
»
Register here
»
- Download brochure
on the e-Learning modules
Related Documents
CARTO XP System brochure
CARTO XP System specifications
Kottkamp H, et al. Electromagnetic versus fluoroscopic mapping of the inferior isthmus for ablation of typical atrial flutter: A prospective randomized study. Circulation. 2000.
Full text
»
Nakagawa H, Jackman WM. Use of a three-dimensional, nonfluoroscopic mapping system for catheter ablation of typical atrial flutter. Pacing Clin Electrophysiol. 1998.
Abstract
»
Stevenson WG, et al. Identification and ablation of macroreentrant ventricular tachycardia with the CARTO electroanatomical mapping system. Pacing Clin Electrophysiol. 1998.
Abstract
»
Gepstein L, et al. A novel method for nonfluoroscopic catheter-based electroanatomical mapping of the heart. In vitro and in vivo accuracy results.
Circulation. 1997.
Full text
»
Shah DC, et al. Three-dimensional mapping of the common atrial flutter circuit in the right atrium. Circulation. 1997.
Full text
»
Shpun S, et al. Guidance of radiofrequency endocardial ablation with real-time three-dimensional magnetic navigation system. Circulation. 1997.
Full text
»