- Diagnostic Products
- Therapeutic Products
- Navigation Products
- CARTO XP EP
Navigation System - CARTOMERGE Image
Integration Software
Module - CARTO RMT
Electroanatomical
Mapping System - THERMOCOOL Irrigated
Tip Catheter and
Integrated Ablation
System - ACUNAV Ultrasound
Catheter - CARTOSOUND Image Integration Module with SOUNDSTAR Catherer
- EZ STEER Bi-Directional
Catheters - LASSO Circular Mapping
Catheter
Therapeutic Products
For more information about each product, click on the arrow [
]
The THERMOCOOL Irrigated Tip Catheter is the first power-controlled open-loop irrigated catheter. It is designed to maintain lower tip-to-tissue temperatures so that electrophysiologists can apply the power needed to create a wider variety of lesion types and effectively monitor catheter tip cooling.
The COOLFLOW Pump delivers saline to the catheter and is specifically designed to work seamlessly with the Stockert 70 RF Generator and the THERMOCOOL Catheter, comprising a totally integrated system.
More information about THERMOCOOL Irrigated Tip Catheter and Integrated Ablation System »
NAVISTAR THERMOCOOL Diagnostic/Ablation Deflectable Tip Catheter is a luminal catheter with a deflectable tip designed to facilitate electrophysiological mapping of the heart and to transmit radiofrequency current to the catheter tip electrode for ablation purposes. Saline, delivered by the COOLFLOW Pump, passes through the lumen of this catheter to maintain lower tip-to-tissue temperature at the ablation site. NAVISTAR THERMOCOOL catheters are available in 5 different curve shapes.
CELSIUS THERMOCOOL Diagnostic/Ablation Deflectable Tip Catheter is a 7F multi-electrode luminal catheter with a deflectable tip designed to transmit radiofrequency current to the catheter tip electrode for ablation purposes. Saline, delivered by the COOLFLOW Pump, passes through the lumen of this catheter to maintain lower tip-to-tissue temperature at the ablation site. CELSIUS THERMOCOOL catheters are available in 4 different curve shapes.
The COOLFLOW Pump delivers a constant flow of saline solution to the catheter tip to keep temperature lower while ablation energy is being delivered to the tissue. It is specifically designed to work seamlessly with the Stockert 70 RF Generator and the THERMOCOOL Catheter.
The Stockert 70 RF Generator utilizes the most advanced RF ablation technology to provide maximum control, exceptional safety, and unrivaled versatility. This generator is indicated for use in conjunction with all Biosense Webster Diagnostic/Ablation Deflectable Tip Catheters for cardiac ablation procedures and is an integral component of the THERMOCOOL Integrated Ablation System.
EZ STEER Bi-Directional Catheter incorporates a patented micro-tensioning system, which allows the catheter tip to be meticulously controlled in very small, continuous, and smooth micromovements. The EZ STEER Bi-Directional Catheter is available in a variety of curve shapes and in two tip electrode sizes, 4 mm and 8 mm.
The NAVISTAR RMT Ablation Catheter is designed to be used solely with the CARTO RMT System and the Niobe® Magnetic Navigation System. This catheter combines the accurate 3-D maps, ablation targeting and temperature control of NAVISTAR technology with the magnetic catheter steering capability of Niobe® technology.
The CELSIUS RMT Ablation Catheter is designed to be used solely with the Niobe® Magnetic Navigation System. This catheter combines the excellent signal quality and temperature control of CELSIUS technology with the magnetic catheter steering capability of Niobe® technology.
Biosense Webster deflectable ablation catheters are available in a wide range of curve types and tip electrode sizes and configurations. Each catheter is handcrafted to precise and demanding specifications, using only the highest-quality materials. A unique multi-step process incorporating proven wire-braiding and extrusion technologies results in excellent torque and maneuverability.
CELSIUS Temperature Sensing Ablation Catheters
- 6F and 7F Quadrapolar Catheter with Non-Braided Tip/Thermistor
- 6F and 7F Quadrapolar Catheter with Non-Braided Tip/Thermocouple
- 7F and 8F Quadrapolar Catheter with 4 mm Braided Tip/Thermistor
- 7F and 8F Quadrapolar Catheter with 4 mm Braided Tip/Thermocouple
- 7F and 8F Quadrapolar Catheter with 5 mm Braided Tip/Thermistor
- 7F and 8F Quadrapolar Catheter with 5 mm Braided Tip/Thermocouple
- 7F and 8F Quadrapolar Catheter with 4 and 5 mm Long Reach Braided Tip/Thermistor
- 7F and 8F Quadrapolar Catheter with 4 and 5 mm Long Reach Braided Tip/Thermocouple
- Wittkampf (Posterioseptal) Catheter/Thermistor
- Wittkampf (Posterioseptal) Catheter/Thermocouple
- 6F Quadrapolar Pediatric Catheter with Non-Braided Tip/Thermistor
- 6F Quadrapolar Pediatric Catheter with Non-Braided Tip/Thermocouple
The CELSIUS DS 8 mm Tip Ablation Catheter combines a longer ablating surface and first-of-its-kind dual sensor temperature control, for greater confidence in atrial flutter ablations.
Key Benefits
Dual thermocouple temperature sensors monitor temperature variance along the entire 8 mm tip
Better temperature control can help prevent low-energy, incomplete ablations or reduce the risk of “hot spots” that can cause charring
Longer tip, with local blood flow cooling, permits delivery of higher power for deeper transmural lesions, resulting in an effective line of conduction block
Creates longer ablation lines per application of RF energy, which may reduce total number of burns and shorten procedure and fluoroscopy times
Compression coil shaft facilitates deflection force and tip responsiveness
Stainless steel braided tip provides torque, flexibility and in-situ stability for improved catheter-to-tissue contact
CELSIUS DS Ablation Catheter
The NAVISTAR DS 8 mm Tip Ablation Catheter combines a longer ablating surface and first-of-its kind dual sensor technology with the ease and guided precision of the CARTO XP System navigation to ensure efficacy of atrial flutter ablation.
Key Benefits
Dual thermocouple temperature sensors monitor temperature variance along the entire 8 mm tip
Better temperature control can help prevent low-energy, incomplete ablations or reduce the risk of “hot spots” that can cause charring
Longer tip, with local blood flow cooling, permits delivery of higher power for deeper transmural lesions, resulting in an effective line of conduction block
Creates longer ablation lines per application of RF energy, which may reduce total number of burns and shorten procedure and fluoroscopy times
Stainless steel braided tip provides torque, flexibility, and in-situ stability for improved catheter-to-tissue contact
NAVISTAR Temperature Sensing Navigation and Ablation Catheters
Teamed with the CARTO XP System and QWIKMAP Software, QWIKSTAR Catheters let you create the equivalent of a 50-point map with just 8 to 10 points, producing a fast “global” snapshot of the chamber that can be continuously refined and updated as new points are acquired. The system lets you capture and map transient events using correct anatomy.
QWIKSTAR Navigation and Ablation Catheters
Non-Temperature Sensing Ablation Catheters
Transeptal access to the left heart has always been acutely challenging. To help meet these challenges, Biosense Webster introduced PREFACE Guiding Sheaths — designed to afford you passage to the left heart with safety, ease and confidence.
Major advantages of the PREFACE Guiding Sheath:
Wire-braided shaft enhances torque, maneuverability
PTFE coated inner surface for reduced friction
Multi-curved design enhances flexibility
Tapered profile for smooth transition between sheath and dilator
Multi-segment design ensures gradual flexibility toward the tip
High-visibility radiopaque, BRITETIP Technology
Low-friction valve provides excellent hemostasis
Side holes help prevent aspiration of sheath against heart wall during withdrawal
Compatible with tungsten-tipped PERRY Dilator
Biosense Webster offers a variety of cables for connecting ablation catheters, RF generators, navigational system junction boxes and patient interface units.
- Cables for CARTO System Junction Box/Patient Interface Unit
- Cables for Catheters with Redel Connector (RT)
- Cables for DS Catheters with Redel 10-Pin Connector (RT)
- Cables for NAVISTAR Catheters
- Cables for NAVISTAR DS Catheters
- Cables for QWIKSTAR Catheters
- Cables for REFSTAR Catheter with QWIKPATCH External Reference Patch
- REFSTAR Catheter with QWIKPATCH External Reference Patch
- Stockert 70 RF Generator and Remote Control Unit Components
- COOLFLOW Pump Irrigation Tubing Set for THERMOCOOL Catheter
- COOLFLOW Pump Optional Accessories
- RF Generators Interface Adapters
- Cables Interface Adapters
General Information
Find out how to use our catalog and understand
the numbering system.
Curve Types and Tips
View the following catheter curves and tip electrode types:
Cable Guide
A quick reference guide to simplify connectivity